Octadecyl Bonded Silica Gel Column

Short Description:

C18 columns are the most commonly used columns in reversed-phase analytical methods. The high-purity silica matrix is bonded with a universal C18 functional group, and multiple blocking makes the column less adsorbed to ionized compounds. The optimized surface design results in a column with a higher specific surface area, higher carbon content, stronger hydrophobic retention, and higher column efficiency, thus ensuring a better separation.

The synthesis of silica gel packing, chemical treatment of silica gel surface, and loading of packing are all tested and controlled by strict quality standards to ensure good batch reproducibility of the column. It is ideal for method development and complex component analysis.

Features and Applications:

Product Name
Reverse Phase C18 Silica Gel

Synonym Octadecyl Bonded Silica Gel

Loading 17% carbon content

Particle Size 1.8 – 60 microns or more

Average Pore Size 100 Å

 

1. High-quality silica gel is used as the matrix. The selected silica particles have excellent surface homogeneity and better mechanical strength, laying a solid foundation for the quality of the packing after bonding; the relatively low column pressure extends the column’s life to a certain extent while making it more convenient for customers to carry out routine maintenance of the column.

2. High column efficiency, sharp and symmetrical peak shape. The unique bonding and capping technology enables the ODS column to maintain symmetrical peak shapes when separating alkaline compounds. High column efficiency allows you to easily meet the column efficiency requirements of various industry testing standards with good batch reproducibility.

HPLC column storage

HPLC Column Storage

1. If the column is not used within 3 days, please rinse the column according to the usual maintenance procedure until the baseline is smooth. Store it in an organic phase/water solution without buffer salts and ion-pair reagents, with the organic phase not less than 20%, and screw the plastic plug with the column to seal it tightly.

2 For long-term storage, it must be stored in 80% methanol or 80% acetonitrile aqueous solution, then remove the column from the instrument and screw the plastic plug to seal it tightly.

FAQ of Octadecyl Bonded Silica Gel Column

1. There has been a debate on the Internet about whether the chromatographic column can be backflushed, what kind of chromatographic column can be backflushed, and what can’t. After recoil, use it forward or backward?

– Generally, the normal-phase column and reversed-phase column should be able to recoil. The purpose of backflushing is to wash away the pollutants at the head of the column. After backflushing, it is better to use it forward, so as to prevent both ends of the column from being polluted. What we have always advocated is forward use and reverse flushing.

 

2. For the commonly used C18 column, how should we activate and maintain it when we get a new chromatographic column? Why do we do this?

– The activation of a new HPLC column is actually a process of equilibrium. In addition to equilibrating with the mobile phase, sometimes it is necessary to equilibrate the new HPLC column with the measured sample, especially for the determination of peptides with relatively high molecular weight. Because the molecular weight is high, the diffusion speed is slow, and the time required for equilibrium is correspondingly longer. The specific balance method is also very simple. The sample is injected several times until the peak area and retention time are stable, and then the formal injection measurement is performed.

If you want to speed up the equilibration time, increase the concentration of the injection sample used for equilibration, or inject multiple needles continuously without waiting for the elution to complete. The purpose of equilibrating the new liquid chromatographic column with the analyte is to saturate the adsorption capacity of the non-specific adsorption sites on the surface of the silica gel matrix filler.

 

3. What kind of HPLC column is generally used for the determination of peptides? The mobile phase is acetonitrile and water, and a small amount of TFA. Especially for short peptides like tripeptides, how should I choose an HPLC column?

– Peptides with low molecular weight can generally be determined by using conventional C18 columns, and ion exchange columns, aqueous C18 columns, and Hilic hydrophilic interaction columns are also available.

Related HPLC Products

Direct-connect UHPLC guard column 2.1 mm for high-pressure LC systems

2.1 mm UHPLC direct-connect guard column with low dead volume design

Home Products HPLC Guard Columns 2.1 mm UHPLC direct-connect guard column with low dead volume design Revolutionary 2.1mm UHPLC Direct-Connect Guard Column Hardware Boost your UHPLC performance with the 2.1mm Direct-Connect Guard Column – superior protection, refined separation. Engineered for ultra-high-performance protection of your analytical columns. Features and Applications: ⭐ Key Features – 2.1 mm

Read More »
New Design 2.1 Direct Connect HPLC Inline Filter

New Design 2.1 Direct Connect HPLC Inline Filter

New 2.1 Direct Connect HPLC Inline Filter Item Number : HP-IF-D2.1n Main Function  2.1mm High Pressure Inline Filter Directly Connect Unique Design  Lower Dead-Volume Easy to Install 316L Stainless Steel 0.2μ,0.5μ,, 2μ Super High Pressure Stainless Steel Frit HPLC Frit accept pore size OEM Service Contact Us Features and Applications: The HPLC inline filter plays

Read More »
Sodium Citrate Reference Standard | CAS 68-04-2

Uridine 5’-triphosphate Trisodium Salt (UTP-Na₃) Reference Standard | CAS 19817-92-6

Uridine 5’-triphosphate Trisodium Salt (UTP-Na₃) Reference Standard | CAS 19817-92-6 | High-Purity Reference Materiel Product Code: U-D25015X Chemical Name: Uridine 5’-triphosphate Trisodium Salt (UTP-Na₃) Category: Drug Impurity Standard CAS Number: 19817-92-6 Molecular Formula: C₉H₁₃N₂Na₃O₁₅P₃ Molecular Weight: 586.12 g/mol Purity: ≥ 95% Available Package Size: 25 mg Storage Conditions: -20 ℃ Special Requirements: Moisture & Air

Read More »

Contact

Phone: +86 800 755 60 20
51-3, Fu 'an West Road, Pinghu Street, Longgang District, Shenzhen City, 518111 China
MON-FRI 09:00 - 19:00, SAT-SUN 10:00 - 14:00