C8 HPLC Columns

USHD C8 HPLC Columns

USHD C8 is a reversed-phase octyl (C8) family, USP L7. The shorter chain retains less strongly than C18, which helps when a C18 method holds analytes too long.

C8-Pro is 150 Å, 7% carbon, in 5 μm and 3.5 μm. USHD C8 is 120 Å, 12% carbon, in 5 μm, 3 μm, 1.8 μm and 1.7 μm. Both are listed for pH 2–8.

Features

Two USP L7 octyl phases. C8-Pro is the lower-carbon, 150 Å option. USHD C8 is the higher-carbon, 120 Å option.

USP L7C8 / octyl120 Å and 150 ÅpH 2–81.7–5 μm
  • USHD C8-Pro — 7% carbon, 200 m²/g, 150 Å, pH 2–8. Lower carbon and a larger pore than USHD C8. Listed for methods that need shorter retention.
  • Double end-capping — Both phases are described with a double end-capping process for peak shape of acidic and basic compounds.
  • USHD C8 — 12% carbon, 320 m²/g, 120 Å, pH 2–8. Higher carbon load, stronger retention and higher selectivity than C8-Pro.
  • Particle sizes on the catalog — C8-Pro: 5 μm and 3.5 μm. USHD C8: 5 μm, 3 μm, 1.8 μm and 1.7 μm.

Return to top

Product Selection

Choose C8-Pro or USHD C8, then confirm the catalog number in the selection table.

C8-Pro

Shorter retention

5 μm and 3.5 μm · 150 Å · 7% carbon
View SKUs →

USHD C8

Stronger C8 retention

5, 3, 1.8 and 1.7 μm · 120 Å · 12% carbon
View SKUs →

C8 vs C18

Compared with C18

Use C8 when a C18 method retains too strongly.
USHD C18 columns →

Return to top

Specifications

Phase specifications for USHD C8-Pro and USHD C8.

PhaseUSPParticle SizePore SizeSurface AreaCarbon LoadpH
USHD C8-ProL75 μm, 3.5 μm150 Å200 m²/g7%2–8
USHD C8L75 μm, 3 μm, 1.8 μm, 1.7 μm120 Å320 m²/g12%2–8

USHD C8-Pro catalog

15 standard sizes. 4.6×250 mm is listed for 5 μm only.

Product No.DimensionsParticle SizePore Size
P1F0B-004692.1×50 mm5 μm150 Å
P1F0B-004702.1×100 mm5 μm150 Å
P1F0B-004713.0×50 mm5 μm150 Å
P1F0B-004723.0×100 mm5 μm150 Å
P1F0B-004734.6×50 mm5 μm150 Å
P1F0B-004744.6×100 mm5 μm150 Å
P1F0B-003494.6×150 mm5 μm150 Å
P1F0B-003484.6×250 mm5 μm150 Å
P1F0B-003392.1×50 mm3.5 μm150 Å
P1F0B-004622.1×100 mm3.5 μm150 Å
P1F0B-004633.0×50 mm3.5 μm150 Å
P1F0B-004643.0×100 mm3.5 μm150 Å
P1F0B-004654.6×50 mm3.5 μm150 Å
P1F0B-004664.6×100 mm3.5 μm150 Å
P1F0B-004674.6×150 mm3.5 μm150 Å

USHD C8 catalog

28 standard sizes, including 1.0 mm ID at 1.7 μm and 3.0×150 / 2.1×150 mm where shown.

Product No.DimensionsParticle SizePore Size
P1F0B-005242.1×50 mm5 μm120 Å
P1F0B-005252.1×100 mm5 μm120 Å
P1F0B-005263.0×50 mm5 μm120 Å
P1F0B-005273.0×100 mm5 μm120 Å
P1F0B-008133.0×150 mm5 μm120 Å
P1F0B-005284.6×50 mm5 μm120 Å
P1F0B-005294.6×100 mm5 μm120 Å
P1F0B-003544.6×150 mm5 μm120 Å
P1F0B-003324.6×250 mm5 μm120 Å
P1F0B-005162.1×50 mm3 μm120 Å
P1F0B-005172.1×100 mm3 μm120 Å
P1F0B-007482.1×150 mm3 μm120 Å
P1F0B-005183.0×50 mm3 μm120 Å
P1F0B-005193.0×100 mm3 μm120 Å
P1F0B-007493.0×150 mm3 μm120 Å
P1F0B-005204.6×50 mm3 μm120 Å
P1F0B-005214.6×100 mm3 μm120 Å
P1F0B-005224.6×150 mm3 μm120 Å
P1F0B-006841.0×50 mm1.7 μm120 Å
P1F0B-006821.0×100 mm1.7 μm120 Å
P1F0B-004752.1×50 mm1.8 μm120 Å
P1F0B-005092.1×100 mm1.8 μm120 Å
P1F0B-007502.1×150 mm1.8 μm120 Å
P1F0B-005103.0×50 mm1.8 μm120 Å
P1F0B-005113.0×100 mm1.8 μm120 Å
P1F0B-007513.0×150 mm1.8 μm120 Å
P1F0B-005124.6×50 mm1.8 μm120 Å
P1F0B-005634.6×100 mm1.8 μm120 Å

Request Quote Ask Method Support

Return to top

Applications

C8 is the intermediate reversed-phase choice between C18 and shorter-chain phases.

Shorter retention than C18

Octyl bonding is less hydrophobic than octadecyl bonding, so many analytes elute earlier. Useful when a C18 method holds peaks too long.

Moderately hydrophobic analytes

Pharmaceuticals, biochemicals and environmental samples that do not need the full retention of a high-carbon C18.

C8-Pro, 150 Å

Lower surface area and a larger pore. The published description is for methods that want reduced retention and better resistance to contamination.

USHD C8, 120 Å

Higher carbon load and surface area for stronger retention and selectivity within the C8 family, including 1.8 μm and 1.7 μm formats.

Related: USHD C18 HPLC columns · All HPLC columns.

Return to top

Support

Include the catalog number if you already have it. Otherwise send phase, particle size and dimensions.

Catalog matching

We confirm P1F0B numbers against phase, dimensions and particle size before quoting.

C18 method conversion

If your current C18 method retains too strongly, send the column size and mobile phase for a C8 suggestion.

Custom dimensions

Sizes that are not in the catalog table can be requested as a custom packed column.

Return to top

FAQ

Answers from the USHD C8 specifications and the current catalog list.

01 What is the difference between USHD C8-Pro and USHD C8?

USHD C8-Pro is 150 Å silica, 200 m²/g, 7% carbon, in 5 μm and 3.5 μm. USHD C8 is 120 Å silica, 320 m²/g, 12% carbon, in 5 μm, 3 μm, 1.8 μm and 1.7 μm. Both are USP L7 and listed for pH 2–8.

02 When should I use C8 instead of C18?

C8 is less hydrophobic than C18, so analytes usually elute earlier. Use it when a C18 column retains the sample too strongly or when a shorter run is required.

03 Which catalog number is the 4.6×250 mm C8 column?

USHD C8-Pro, 5 μm, 150 Å, 4.6×250 mm is P1F0B-00348. USHD C8, 5 μm, 120 Å, 4.6×250 mm is P1F0B-00332. The 3.5 μm C8-Pro and 3 μm C8 lists do not include a 4.6×250 mm size.

04 What is the 1.7 μm size?

Two USHD C8 catalog rows are 1.7 μm, 120 Å: P1F0B-00684 (1.0×50 mm) and P1F0B-00682 (1.0×100 mm). The other sub-2 μm sizes in this list are 1.8 μm.

05 Can other dimensions be made?

The table is the standard catalog. Other internal diameters and lengths can be requested as a custom column.

Return to top

Need a size matched to your method?

Request a USHD C8 Quote

Send the catalog number, or the phase, dimensions and particle size. We will confirm availability and pricing.

Helpful to include:

  • Catalog number, or phase and dimensions
  • Particle size (5 / 3.5 / 3 / 1.8 / 1.7 μm)
  • Current C18 or C8 brand, if replacing one
  • Quantity and destination

Prefer email? [email protected] · Contact Us

UHPLCS Technical Inquiry