Amino Acid HPLC Columns
Hsol Amino Acid HPLC Column
Hipsoul® (uHPLCs®) Hsol Amino is an HPLC specialty column designed for natural and synthetic amino acids—high polarity, ionization and isomer-rich samples.
Optimized stationary-phase chemistry, particle-size distribution and packing deliver precise separation and faster detection for biochemistry, food testing, pharmaceutical R&D and agricultural analysis.
Catalog formats: 4.6 × 250 mm, 3 μm / 5 μm, 120 Å (P1F0B-00733 / P1F0B-00726), compatible with UV, FLD, PDA and MS detectors.
Hsol Amino Acid HPLC Column
Features
Built for amino acid polarity, ionization and isomer separation—with efficient peaks for routine HPLC workflows.
- High-selectivity separation — Stationary phase tuned for amino/carboxyl groups and side-chain structure; resolves isomers such as leucine/isoleucine and common derivatives (OPA / FMOC / PITC).
- Efficient, faster runs — Narrow particle-size distribution (3 μm designs) with optimized packing; theoretical plate count ≥ 15,000 N/m, high resolution and symmetric peaks (tailing factor ≤ 1.2). Typical single-sample analysis can be shortened to about 15–30 minutes.
- Broad method compatibility — Supports reversed-phase, ion-exchange and hydrophilic-interaction modes for matrices such as biofluids, food extracts, fermentation broths and drug preparations; compatible with mainstream derivatization methods.
- Stability for routine use — High-purity silica reduces metal-impurity interference. Continuous service life can reach about 500–1,000 injections with gradual efficiency loss. Polymer-matrix options are available where stronger acid/base resistance is required.
- Low detection limits — Strong fit with fluorescence and MS detection; amino acid LOD can reach about 0.1–1.0 μmol/L for trace analysis needs.
Product Selection
Start from the catalog 4.6 × 250 mm formats, then confirm the particle size and product number.
Additional dimensions and particle sizes can be customized—contact our sales engineers.
Specifications
Core packing and operating specifications for the Hsol Amino acid specialty column.
| Parameter | Specification |
|---|---|
| Stationary Phase / Matrix | High-purity silica |
| Particle Size | 3 μm, 5 μm |
| Pore Size | 120 Å |
| Column Format (catalog) | 4.6 × 250 mm |
| pH Range | 1.0 – 8.0 |
| Max. Operating Temperature | 60 °C (typical) |
| Pressure Rating | ≤ 40 MPa |
| Compatible Detectors | UV, FLD, PDA, MS |
| Catalog Product Nos. | P1F0B-00733 (3 μm), P1F0B-00726 (5 μm) |
Product selection table
Catalog SKUs from the product specification sheet. Additional specifications can be customized.
| Product No. | Dimensions (mm) | Particle Size | Pore Size |
|---|---|---|---|
| P1F0B-00733 | 4.6×250 mm | 3 μm | 120 Å |
| P1F0B-00726 | 4.6×250 mm | 5 μm | 120 Å |
Applications
Use cases from the Hsol Amino specification for food, pharma, clinical and agricultural amino acid work.
Biomedical analysis
Free amino acids in plasma, urine and CSF (e.g. metabolic-disorder panels) and amino acid composition of protein hydrolysates.
Food and nutraceuticals
Essential amino acids in dairy, supplements and infant formula; amino acid nitrogen in fermented foods such as soy sauce and vinegar.
Pharma R&D and QC
Purity of amino acid APIs/formulations (e.g. glutamine, alanine), impurity control in peptide synthesis, and D/L amino acid purity checks.
Feed & agriculture
Lysine, methionine and other amino acids in feed (e.g. GB/T 18246-2021 workflows) and free amino acid metabolism in plant tissues.
Typical application focus
- Fermented food QC — Amino acid nitrogen grading (e.g. soy sauce special/first grade thresholds ≥ 0.8 / ≥ 0.7 g/100 mL) and free amino acid profiles.
- Label claim verification — Amino acid oral liquids, protein powders, collagen/glycine claims and similar nutraceutical checks.
- Pharmacopoeial purity — Support for ChP / USP-style impurity control targets (e.g. impurity content ≤ 0.5% where required by the method).
Application Cases
Chromatogram data from product documentation using Hipsoul® (uHPLCs®) Hsol Amino, 5 μm, 120 Å, 4.6 × 250 mm.
Amino acid peak table
| No. | Name | Retention Time (min) | Peak Area (mAU·s) | Peak Height (mAU) | Plate Count | Resolution |
|---|---|---|---|---|---|---|
| 1 | Asp | 5.240 | 62.632 | 11.072 | 20455 | / |
| 2 | Glu | 6.005 | 66.495 | 9.375 | 17305 | 4.64 |
| 3 | Ser | 10.835 | 168.057 | 18.558 | 34085 | 23.11 |
| 4 | Gly | 11.795 | 277.326 | 29.502 | 36746 | 3.99 |
| 5 | His | 12.747 | 124.931 | 13.071 | 42137 | 3.84 |
| 6 | Arg | 14.798 | 113.727 | 11.242 | 50163 | 7.99 |
| 7 | Thr | 15.519 | 144.996 | 13.518 | 48450 | 2.64 |
| 8 | Ala | 16.423 | 199.713 | 18.937 | 57542 | 3.24 |
| 9 | Pro | 17.394 | 177.979 | 18.888 | 81149 | 3.74 |
| 10 | Tyr | 22.914 | 133.321 | 17.407 | 215383 | 24.95 |
| 11 | Val | 24.592 | 140.845 | 17.273 | 220219 | 8.23 |
| 12 | Met | 25.892 | 119.551 | 14.173 | 226656 | 6.08 |
| 13 | Cys | 28.639 | 55.190 | 4.388 | 107390 | 9.67 |
| 14 | Ile | 29.327 | 179.127 | 20.325 | 275194 | 2.39 |
| 15 | Leu | 29.819 | 145.972 | 15.885 | 264178 | 2.16 |
| 16 | Trp | 32.596 | 134.183 | 15.349 | 338373 | 12.16 |
| 17 | Phe | 33.407 | 130.272 | 15.503 | 377610 | 3.66 |
| 18 | Lys | 34.450 | 239.833 | 52.749 | 1372045 | 6.22 |
Test note: with the Hsol Amino 5 μm, 120 Å, 4.6 × 250 mm column under these conditions, resolution between peaks should meet the testing requirements.
Care & Use
Activation, sample prep, mobile phase and storage guidance from the product specification.
- Activation — Before first use, flush with methanol/acetonitrile (50:50) for 30 minutes at 1.0 mL/min, then equilibrate with mobile phase until the baseline is stable.
- Sample preparation — Derivatize amino acids when required; avoid high salt/protein contamination of the bed; filter with a 0.22 μm membrane.
- Mobile phase — Reversed-phase commonly uses methanol or acetonitrile with aqueous phosphate/acetate buffers; ion-exchange often uses pH gradient elution. Avoid strongly corrosive solvents (e.g. concentrated HCl or NaOH).
- Storage — Short term (≤ 1 week): methanol/water (80:20). Long term (≥ 1 month): pure methanol; store at 4–30 °C in a cool, dry place away from direct sunlight.
- Maintenance — After use, flush with mobile phase 10–15 minutes, then methanol ~20 minutes. If pressure rises abnormally, reverse-flush with methanol at low flow (0.5 mL/min) or replace the guard column.
Support
Technical support commitments from the Hsol Amino product documentation.
Complimentary method consultation
Method development and optimization support for amino acid detection workflows.
Rapid technical response
Professional technical support available 24/7, with troubleshooting solutions provided within 48 hours.
Quality consistency assurance
Each batch undergoes quality control for consistent performance parameters and is supplied with a test report.
FAQ
Answers based on the Hsol Amino product specification sheet.
01 What is the Hsol Amino column designed for?
It is an HPLC column optimized for amino acids (natural and synthetic), including polar, ionizable species and isomers such as leucine/isoleucine, as well as common derivatives (OPA / FMOC / PITC).
02 Which particle sizes and catalog SKUs are available?
Catalog sizes are 4.6 × 250 mm with 3 μm (P1F0B-00733) and 5 μm (P1F0B-00726), both 120 Å. Additional specifications can be customized—contact our sales engineers.
03 What pH and pressure limits apply?
The documented operating window is pH 1.0–8.0, typical maximum temperature 60 °C, and pressure rating ≤ 40 MPa.
04 Which detectors are compatible?
UV, fluorescence (FLD), diode-array (PDA) and mass spectrometry (MS) detectors are listed as compatible in the product specification.
05 Do amino acid samples require derivatization?
Yes for most workflows—amino acids typically require derivatization (except when using a non-derivatization column workflow). Filter samples with a 0.22 μm membrane and avoid high salt or protein load on the bed.
06 What support is included?
Complimentary method consultation for amino acid analysis, technical support with troubleshooting guidance within 48 hours, and a test report with each column batch.
Need help matching your method?
Request an Hsol Amino Quote
Share your amino acid method, particle size preference and quantity — we’ll confirm catalog SKUs and reply with availability and pricing.
Helpful to include:
- Current brand / dimensions
- Particle size (3 / 5 μm)
- Derivatization method (OPA / FMOC / PITC)
- Quantity / destination
Prefer email? [email protected] · Contact Us