C18 HPLC Columns

ValuSil C18 Chromatography Column

ValuSil C18 is a cost-effective HPLC column. It uses a high-purity silica matrix bonded with an octadecyl (C18) stationary phase and is fully end-capped.

While meeting the USP L1 classification, it provides stable and reliable separation performance at an economical price—designed for routine analytical testing with consistent, traceable chromatographic data and pharmacopoeial-method compatibility.

It helps control procurement costs while meeting regulatory requirements, providing a balanced return on investment for QC, food testing, CRO and method-development labs.

Features

Pick the ValuSil C18 for your needs—USP L1 performance with controlled cost.

USP L1120 Å328 m²/g16.4% CFully end-cappedRT RSD ≤ 1.5%
  • Compliance with USP L1 — Pharmacopoeial or registration methods developed with L1 columns can be transferred directly without redevelopment and revalidation.
  • High-purity silica with strict metal-impurity control — Weakens secondary interactions, improves peak shape for basic samples, and reduces adsorption losses of polar components.
  • Full end-capping — Improves peak symmetry for basic substances such as amines and alkaloids; reduces peak tailing for reliable resolution and quantitation.
  • Good batch-to-batch reproducibility — Multi-batch testing shows retention-time RSD ≤ 1.5%, supporting high-throughput labs after column-batch changes.

Return to top

Product Selection

Choose by particle size, then confirm the catalog SKU in the selection table. Additional specifications can be customized.

1.8 μm

UHPLC / fast LC

2.1×50, 2.1×100, 3.0×50, 3.0×100 mm · 120 Å
View SKUs →

3 μm

Balanced analytical

2.1×100, 3.0×50, 3.0×100, 4.6×100 mm · 120 Å
View SKUs →

5 μm

Routine HPLC

4.6×150, 4.6×250 mm · 120 Å
View SKUs →

Return to top

Specifications

Core stationary-phase and packing specifications for ValuSil C18.

ParameterSpecification
Stationary PhaseOctadecyl-Bonded Silica (C18)
USP ClassificationL1
Particle Size1.8 μm, 3.0 μm, 5 μm
Pore Size120 Å
Specific Surface Area328 m²/g
Carbon Load16.4%
End-CappingFully End-Capped

Product selection table

Ten standard catalog sizes. Additional specifications can be customized—contact our sales engineers.

Product No.Dimensions (mm)Particle SizePore Size
P1F0B-009162.1×50 mm1.8 μm120 Å
P1F0B-009152.1×100 mm1.8 μm120 Å
P1F0B-009143.0×50 mm1.8 μm120 Å
P1F0B-009133.0×100 mm1.8 μm120 Å
P1F0B-009122.1×100 mm3 μm120 Å
P1F0B-009113.0×50 mm3 μm120 Å
P1F0B-009103.0×100 mm3 μm120 Å
P1F0B-009094.6×100 mm3 μm120 Å
P1F0B-009074.6×150 mm5 μm120 Å
P1F0B-009084.6×250 mm5 μm120 Å

Request Quote Ask Method Support

Return to top

Applications

Cost-effective USP L1 performance for pharmaceutical QC, food compliance, CRO throughput and academic method work.

Pharmaceutical R&D and QC

Assay and related-substance testing of chemical-drug APIs and active ingredients in natural medicines. Supports GMP quality control and method transfer.

Food-safety monitoring

Preservatives, synthetic colorants, pesticide residues, vitamins and other food components—suited to complex matrices and compliance screening.

Third-party testing and CRO

Routine testing across pharmaceuticals, foods and environmental samples. Good batch reproducibility and a complete COA support audits.

Research institutes and universities

Conventional reversed-phase method exploration, reference-standard separation and high-volume screening with balanced performance and cost.

Return to top

Application Cases

Results from product documentation using Hipsoul® (uHPLCs®) ValuSil C18, 5 μm, 120 Å, 4.6 × 250 mm.

Prednisone Acetate tablet

No.NameRetention Time (min)Peak Area (mAU·s)Peak Height (mAU)Plate CountResolution
1Peak 121.7177.249722.02E-017768/
2Peak 226.2777.118351.66E-0175884.15
3Peak 330.6331.977181.59E-011465615.7
4Peak 4 Prednisone33.6623402.79492559.8743371382312.61
5Peak 533.92917.231092.62196272561.61
6Peak 635.5654.52E-018.99E-02107248710.58

Test results: resolution between all peaks was greater than 1.5, meeting the testing requirements.

Water-soluble vitamin mixed standard

Peak NameRetention Time (min)Peak AreaResolution (USP)Tailing FactorPlate Count (USP)
Vitamin C2.7094576.52539/1.179803251
Vitamin B93.3972375.958503.931.375007265
Vitamin B63.9371249.223273.631.1016913116
Vitamin B54.6493788.576174.571.0893211503
Vitamin B1216.0191094.0921668.491.12805164052
Vitamin B217.477306.359773.451.03030157527

Test results: under these chromatographic conditions, the resolution of all vitamins met the testing requirements.

Return to top

Support

Technical support for method comparison, troubleshooting and quality documentation.

Complimentary method consultation

Guidance on method comparison and conversion between ValuSil C18 and leading-brand C18 columns.

Rapid technical response

Professional technical support available 24/7, with troubleshooting solutions provided within 48 hours.

Quality consistency assurance

Each batch undergoes quality control for consistent performance parameters and is supplied with a test report.

Return to top

FAQ

Answers based on product specifications and support commitments.

01 Is ValuSil C18 USP L1 compliant?

Yes. The ValuSil C18 bonded phase meets the USP L1 classification for octadecylsilane-bonded silica, a reversed-phase stationary phase widely used in pharmacopoeias and drug standards.

02 What particle sizes are available?

ValuSil C18 is offered in 1.8 μm, 3.0 μm and 5 μm particle sizes, all with 120 Å pore size. Additional specifications can be customized—contact our sales engineers.

03 How reproducible is batch-to-batch retention?

Testing across multiple batches shows a retention-time RSD of ≤ 1.5%, with low column-to-column and batch-to-batch variation.

04 Is the column fully end-capped?

Yes. Thorough end-capping improves peak symmetry for basic substances such as amines and alkaloids and reduces peak tailing.

05 What applications is ValuSil C18 suited for?

Typical uses include pharmaceutical R&D and QC, food-safety monitoring, third-party testing and CRO laboratories, and method development in research institutes and universities.

06 What support do you provide after purchase?

Complimentary method consultation, technical support with troubleshooting solutions within 48 hours, and a test report supplied with each column batch.

Return to top

Need help matching your method?

Request a ValuSil C18 Quote

Share your current C18 brand, dimensions, particle size and quantity — we’ll match a ValuSil size and reply with availability and pricing.

Helpful to include:

  • Current brand / dimensions
  • Particle size (1.8 / 3 / 5 μm)
  • Application or USP method
  • Quantity / destination

Prefer email? [email protected] · Contact Us

UHPLCS Technical Inquiry