HPLC and UHPLC hardware
HPLC Consumables
Filters, guard columns, frits, capillary tubing, fittings, sample loops and empty column hardware for the LC flow path. Choose the family that matches the instrument, or send a part number for a quote.
Packed analytical columns stay on the HPLC columns pages. This page is the hardware around them.
Stainless steel and PEEK
Analytical through preparative
Catalog parts and OEM builds
Quote from a part number or drawing
Where the part sits in the system
Start from the position you are replacing.
-
01
Solvent inlet
A reservoir filter keeps particles out of the pump.
-
02
Pump and column lines
Capillary tubing and fittings set the OD, ID and connection.
-
03
Injector
The sample loop sets the injection volume on the valve.
-
04
Before the column
Inline filters catch particles. Guard columns protect the packing.
-
05
Column hardware
Empty tubes, frits and packing material for labs that pack their own columns.
-
06
Baseline problems
Ghost buster columns for mobile-phase peaks. Peak smooth columns for solvent mismatch.
HPLC consumable families
Open a family for sizes, materials and a quote.
Protect the column and the baseline
Solvent reservoir
HPLC Inlet Filters
Suction filters for the solvent bottle and the pump inlet. View inlet filters
Before the column
HPLC Inline Filters
Frit filters for the line between the injector and the column, analytical through preparative. View inline filters
Column inlet
HPLC Guard Columns
Cartridge and direct-connect guards for analytical, UHPLC and preparative columns. View guard columns
Mobile phase
Ghost Buster Columns
Installed before the injector to trap mobile-phase impurities that show up as ghost peaks. View ghost buster columns
After the injector
Peak Smooth Columns
Direct-connect, rotary and compact types for peak splitting caused by sample solvent mismatch. View peak smooth columns
Column end
HPLC Frits
316L stainless steel and PEEK frit discs for column ends and filter bodies. View HPLC fritsCarry the flow and make the connection
Flow lines
HPLC Capillary Tubing
1/32″ and 1/16″ OD stainless steel capillary tubing. Catalog lengths include fittings. View capillary tubing
Ports and unions
HPLC Fittings and Connectors
Stainless steel, PEEK and PCTFE unions, tees, crosses and adapters. View fittings
Injector
HPLC Sample Loops
Stainless steel and PEEK injection loops, matched to the valve and the volume. View sample loopsPack a column or prepare solvent
Column tube
Empty HPLC Column Hardware
316L empty column tubes from 2.1 mm analytical hardware to 50 mm preparative tubes. Supplied unpacked. View empty columns
Stationary phase
HPLC Column Packing Material
Silica-based packing. Select particle size, pore size and bonded phase for bulk or sample quantities. View packing material
Solvent preparation
Vacuum Filtration Apparatus
Multi-station vacuum filtration hardware for solvent and sample cleanup, with interchangeable membranes. View filtration apparatusWhich consumable to quote
Send the dimensions that separate a catalog part from a custom one.
| Job | Start here | Include in the quote |
|---|---|---|
| Keep particles out of the pump | Inlet filter | Stem or body size, pore size, bottle or instrument |
| Catch particles before the column | Inline filter | Column ID, connection, frit pore size |
| Protect the analytical packing | Guard column | Column ID, chemistry, pressure class, connection |
| Ghost peaks from the mobile phase | Ghost buster column | HPLC or UHPLC system, gradient, column size |
| Split peaks from the injection solvent | Peak smooth column | Column ID, injection solvent, install position |
| Replace a flow line or port | Capillary tubing or fittings | OD, ID, length, thread, instrument brand |
| Set the injection volume | Sample loop | Valve model, volume, stainless steel or PEEK |
| Pack your own column | Empty hardware, frits, packing | ID, length, phase, particle size, pore size |
| Filter solvent before use | Vacuum filtration apparatus | Number of stations, membrane, solvent |
OEM HPLC consumables
Private label, custom length and drawing-based parts.
Instrument makers and distributors use the same families for private label and replacement parts. Custom length, sleeve, fitting and packaging are quoted from a drawing or a sample.
See OEM and custom capabilities, or send the requirement on the form below.
HPLC consumables FAQ
Before you send a part number.
What does this HPLC consumables page cover?
Hardware around the analytical column: guard columns, ghost-peak traps, peak-smooth columns, inline and inlet filters, frits, capillary tubing, fittings, sample loops, empty column tubes, packing materials and vacuum filtration apparatus. Packed HPLC columns are listed separately.
Should I choose a guard column or an inline filter?
A guard column sits at the analytical column inlet and is replaced to protect the packing from sample contaminants. An inline filter is a frit body in the flow path that catches particles. Many systems use both. Match the column ID and the connection before ordering.
Can HIPSOUL supply OEM HPLC consumables?
Yes. Custom lengths, private-label packaging and drawing-based fittings or hardware can be quoted. Send the drawing or the existing part number.
What should I send for a quotation?
Product family, dimensions or volume, material, connection, instrument brand or existing part number, and quantity. A photo of the installed part helps when a drawing is not available.
Where are the packed HPLC columns?
Packed USHD columns, including C18, C8, HILIC, PFP, phenyl, SEC, normal phase, preparative and UHPLC columns, are on the HPLC columns pages. This page is the hardware and consumables around those columns.
Need a part for this flow path?
Request HPLC Consumables Pricing
Tell us the product family, dimensions, material and instrument. We will confirm a listed part or quote a custom piece.
Helpful to include:
- Product family
- Dimensions or volume
- Material and connection
- Instrument or existing part number
Prefer email? [email protected] · Contact Us