Skip to content
uhplcs logo 2023

OD Tubing - Inlet Solvent Filter

Inlet Solvent Filter - OD Tubing OEM Supplier

Inlet solvent filter outside diameter connector in High-Performance Liquid Chromatography (HPLC) is an essential component of the HPLC system. It is a small filter located at the inlet of the HPLC column. Before entering the column, it removes any impurities or particulate matter from the solvent.

The connector is typically made of stainless steel or other inert materials and has a precise outside diameter to ensure a secure and leak-free connection to the HPLC system. It is designed to fit tightly onto the inlet of the column, creating a seal that prevents any solvent leakage.

Inlet solvent filter outside diameter connector in High-Performance Liquid Chromatography (HPLC) is an essential component of the HPLC system. It is a small filter located at the inlet of the HPLC column. Before entering the column, it removes any impurities or particulate matter from the solvent.

The connector is typically made of stainless steel or other inert materials and has a precise outside diameter to ensure a secure and leak-free connection to the HPLC system. It is designed to fit tightly onto the inlet of the column, creating a seal that prevents any solvent leakage.

OD TUBING

HPLC
INLET FILTER

OEM HPLC Solvent Inlet Filter Out Tubing Connetor

OEM HPLC Solvent Inlet Filter Out Tubing Type

Pore Size :  2μ,5μ,10μ,20μ
Tubing Size :  1 / 16″  ;  1 / 8″
Size:  D9.5 * L33.0  ;  D12. 7* L 28.5 ; D12.7 x L 32.2

HPLC Solvent Inlet Filter Out Tubing Connetor

HPLC Solvent Inlet Filter Out Tubing Connetor

Pore Size :  2μ,5μ,10μ,20μ
Tubing Size :  1 / 16″  ;  1 / 8″
Size:  D9.5 * L33.0  ;  D12. 7* L 28.5 ; D12.7 x L 32.2

Special inlet solvent filter

Special HPLC Inlet Solvent Filter

Pore Size :  2μ,5μ,10μ,20μ
Tubing Size :  1 / 16″  ;  1 / 8″
Size:   D12. 7 , OEM Size Available

OEM inlet solvent filter

OEM inlet solvent filter

Pore Size :  2μ,5μ,10μ,20μ
Tubing Size :  1 / 16″  
Size:   D12. 0 , OEM Size Available

Peek inlet solvent filter

Peek inlet solvent filter

Pore Size :  2μ,5μ,10μ,20μ
Tubing Size :   1 / 8″
Size:   D12. 0 , OEM Size Available

GET HPLC E-CATALOGUE

Get More Details of HPLC Products by 2023 New E-Catalogue from uHPLCs

Main Features

The inlet solvent filter outside diameter connector in High-Performance Liquid Chromatography (HPLC) is a critical component of the HPLC system that offers several important features, including:

  1. Precise outside diameter: The connector has a precise outside diameter that allows it to fit tightly onto the inlet of the column, creating a secure and leak-free connection. 
  2. Compatibility: The connector is compatible with a range of HPLC columns and systems, making it a versatile component used in various laboratory settings. 
  3. Material: The connector is typically made of inert materials such as stainless steel or PEEK, which ensures that it does not react with the solvents or samples being analyzed. 
  4. Filter: The connector contains a filter that removes any impurities or particulate matter from the solvent before it enters the column, which helps to maintain the quality and purity of the sample being analyzed. 
  5. Easy replacement: The inlet solvent filter outside diameter connector is designed to be easily replaced, allowing for quick and easy maintenance of the HPLC system. 
  6. Longevity: The connector is a durable component that can withstand frequent use and maintain its performance over time. 

Overall, the inlet solvent filter outside diameter connector in HPLC is a critical component of the system that ensures the accuracy and reliability of the results obtained from HPLC analysis. Its precise design, compatibility, and durability make it an essential tool for laboratory professionals working with HPLC systems.

Trust us by Certifications & Patent

Country Export
0
Production Area
0
Staff
0
Low MOQ
0
Production Time
0

Effective OEM Service

uHPLCs is the factory, your go-to source for OEM services for the Inlet Solvent Filter Outside Diameter Connector in HPLC. We understand that quality, precision, and performance are critical for HPLC analysis, and we are committed to providing you with a solution that meets your needs.

With OEM services, you can work with our expert team to create a custom Inlet Solvent Filter Outside Diameter Connector in HPLC tailored to your unique requirements. We use state-of-the-art technology and high-quality materials to ensure that our connectors are durable, reliable, and deliver optimal performance.

We offer a wide range of customization options, including different filter sizes, materials, and connector designs, so you can get exactly what you need for your HPLC system. We also provide private labelling and custom packaging options to help you maintain your brand identity and streamline your workflow.
Our commitment to quality, precision, and customer satisfaction sets us apart from the competition. Contact us today to learn more about how our OEM services for Inlet Solvent Filter Outside Diameter Connector in HPLC can help you optimize your laboratory processes and achieve your goals.

High Quality HPLC Column 316L, 316 Stainless Steel Tube Materials

Design New HPLC Columns 100% As Clients Request

Make HPLC Column Samples And Test Before Mass Products.

What Clients Say

Contact Salesman

Interested in purchasing or learning more about the Inlet Solvent Filter Outside Diameter Connector in HPLC? Contact our knowledgeable sales team today to discuss your specific needs and find the right solution for you. Click the button below to Contact us Now !

High Quality HPLC Column 316L, 316 Stainless Steel Tube Materials

Design New HPLC Columns 100% As Clients Request

Make HPLC Column Samples And Test Before Mass Products.

HPLC Column FAQ

HPLC Applications

The Inlet Solvent Filter Outside Diameter Connector in HPLC has many applications in various industries. Some potential applications include:

  1. Pharmaceutical industry: The Inlet Solvent Filter Outside Diameter Connector is used in the production of pharmaceutical products. It ensures the purity and accuracy of drug formulations and can be used to analyze drug metabolites and degradation products.

  2. Environmental testing: The Inlet Solvent Filter Outside Diameter Connector can be used to test for the presence of contaminants in environmental samples, such as water and soil. It enables the separation and analysis of complex mixtures and can be used to identify and quantify pollutants.

  3. Food and beverage industry: The Inlet Solvent Filter Outside Diameter Connector can be used to analyze the composition and quality of food and beverage products. It can detect additives, preservatives, and other contaminants, as well as identify and quantify essential nutrients.

  4. Forensic testing: The Inlet Solvent Filter Outside Diameter Connector is used in forensic laboratories to analyze biological and chemical samples. It can be used to identify trace amounts of drugs, explosives, and other compounds, and can be used to analyze DNA and other biomolecules.

  5. Research and development: The Inlet Solvent Filter Outside Diameter Connector is a critical component in many research applications, including the development of new materials, biomolecules, and pharmaceuticals. It enables high-resolution separations and accurate analyses, providing researchers with valuable data for their experiments.

HPLC solvent filter od tubing series

Why is the HPLC solvent filter head designed as an external tube style? ( OD Tubing )

The design of an HPLC (High-Performance Liquid Chromatography) solvent filter head as an external pipe style serves several important purposes and offers advantages in the operation and maintenance of the HPLC system. Here are some reasons for this design choice:

  1. Easy Access for Maintenance: An external pipe-style solvent filter head is designed to be easily accessible from the outside of the HPLC system. This accessibility simplifies routine maintenance and replacement of filter elements or cartridges. Users can quickly inspect and replace filters without the need to disassemble the system, reducing downtime.

  2. Minimizing Contamination Risk: External filter heads are typically positioned before the solvent enters the HPLC pump and column. Placing the filter externally helps prevent any potential contaminants or particulate matter from entering the critical components of the system, such as the pump and column. This design minimizes the risk of clogging and damage to these components.

  3. Versatility: External filter heads are often designed to accommodate various types and sizes of filter cartridges or elements. This versatility allows users to choose filters that are best suited for their specific applications or solvent requirements without having to modify the internal structure of the HPLC system.

  4. Pressure Regulation: Some external filter heads incorporate pressure regulation mechanisms. This feature helps maintain a consistent solvent flow rate and pressure into the HPLC system, which is crucial for stable and reproducible chromatographic results.

  5. Reduced Risk of Contaminant Release: In the event of a filter failure or breakthrough, an external filter head design can help contain any potential contaminants within the filter housing. This containment prevents contaminants from reaching the sensitive areas of the HPLC system, enhancing system safety.

  6. Easy Visual Inspection: The external placement of the filter head allows for easy visual inspection of the filter element’s condition. Users can check for signs of contamination or clogging without disassembling the system.

  7. Compatibility: External filter heads can be integrated into various HPLC system configurations, making them compatible with a wide range of instruments and setups.

In summary, the external pipe-style design of an HPLC solvent filter head offers practical advantages in terms of maintenance, contamination control, versatility, and compatibility. It ensures that the solvent entering the HPLC system is as clean and free from contaminants as possible, contributing to the reliability and accuracy of chromatographic analyses.

Frequently Asked Questions

An Inlet Solvent Filter Outside Diameter Connector in HPLC is a component used to connect the solvent inlet line to the HPLC system. It contains a filter to remove particulate matter and debris from the solvent, which can cause damage to the system.

An Inlet Solvent Filter Outside Diameter Connector is necessary in HPLC to ensure the purity and accuracy of the solvents used in the analysis. Particulate matter and debris can damage the system, affect the accuracy of the analysis, and reduce the lifespan of the columns.

Inlet Solvent Filter Outside Diameter Connector in HPLC can be made from various materials, including stainless steel, PEEK, and titanium. The choice of material depends on the compatibility with the solvents used, the pressure requirements, and the budget.

Inlet Solvent Filter Outside Diameter Connector in HPLC is typically designed to be compatible with a specific type of HPLC system. It’s important to ensure compatibility before purchasing and installing the connector.

The frequency of replacing an Inlet Solvent Filter Outside Diameter Connector in HPLC depends on the sample matrix and the frequency of use. It’s recommended to replace the filter regularly to prevent damage to the system and ensure accurate results.

Inlet Solvent Filter Outside Diameter Connector in HPLC should not be cleaned but rather replaced. Cleaning the filter can lead to damage or contamination of the system.

Inlet Solvent Filter Outside Diameter Connector in HPLC is typically designed to be used with high-pressure systems. Using it with a low-pressure system may result in leaks or damage to the connector.

Some manufacturers offer OEM services that allow customization of the Inlet Solvent Filter Outside Diameter Connector in HPLC. Customization options may include material, filter size, and other specifications to meet specific needs.

Need Help ?

Contact uHPLCs Today for Any Questions for HPLC / UHPLC 

+(86) 0755-28502380

sales@uhplcs.com

Contact Us

Recent Posts

Hotsale HPLC Products

Pre 50mm Empty HPLC Columns hardware

50mm Empty HPLC Columns

Previous slide Next slide 50mm Empty HPLC Columns Wholesale and OEM Manufacturer Short Description: UHPLC Empty Column Hardware (Each column blank kit) includes a precision-bore

Read More »
20mm Empty HPLC Columns hardware

20mm Empty HPLC Columns

Previous slide Next slide 20mm Empty HPLC Columns 316L Stainless Steel Short Description: UHPLC Empty Column Hardware (Each column blank kit) includes a precision-bore polished

Read More »

Contact

Email: sales@uhplcs.com
Phone: +86 0755 28502380
51-3, Fu 'an West Road, Pinghu Street, Longgang District, Shenzhen City, 518111 China
We Will Send Back Your Inquiry Within 48-Hours

Can’t Get Enough?

Get More Information and Quotation
for Our HPLC Column Hardware Today !

Subscribe for exclusive offers and updates on new arrivals