2.1 mm Direct-Connect HPLC/UHPLC Inline Filter

Low Dead Volume. High-Pressure Filtration. Reliable Column Protection.

Item Number: HP-IF-D2.1n

Designed for analytical HPLC and UHPLC applications, the HP-IF-D2.1n direct-connect inline filter removes particulate contaminants before they reach the analytical column. Its compact design minimizes additional connection volume and simplifies routine maintenance.

  • 2.1 mm direct-connect design — compact connection with low dead volume.
  • High-pressure filtration — designed for demanding HPLC and UHPLC applications.
  • 316L stainless steel — durable metal construction.
  • Replaceable stainless steel frit — simplified maintenance.
  • Multiple pore sizes — 0.2 μm, 0.5 μm and 2 μm.
  • OEM customization — additional frit pore sizes available on request.

Features & Applications

The HP-IF-D2.1n inline filter provides an additional particulate filtration barrier in liquid chromatography flow paths. It helps protect analytical column inlet frits and packing materials from contamination while minimizing unnecessary extracolumn volume.

Key Features

Direct-Connect Design

Compact connection geometry reduces the need for additional connecting tubing and fittings when used with compatible ports.

Low Dead Volume

Minimizes additional flow-path volume to help reduce extracolumn band broadening in analytical LC applications.

High-Pressure Construction

Designed for high-pressure liquid chromatography applications with compatible connections and operating conditions.

316L Stainless Steel

Durable stainless steel construction suitable for compatible chromatography solvents and operating conditions.

Replaceable Filter Frit

The replaceable stainless steel frit simplifies routine maintenance without replacing the complete filter assembly.

Custom Filtration Options

Standard pore sizes include 0.2 μm, 0.5 μm and 2 μm. Additional pore sizes are available through OEM customization.

Typical Applications

Analytical HPLC

  • Mobile phase particulate filtration
  • Analytical column protection
  • Routine laboratory analysis

UHPLC Applications

  • Low-volume analytical flow paths
  • Fine-particle column protection
  • High-pressure LC configurations

Pharmaceutical Analysis

  • Drug quality control
  • Analytical method development
  • Routine pharmaceutical testing

Compact Direct-Connect Installation

The direct-connect structure simplifies installation and reduces additional connection volume. Its compact configuration is particularly useful in analytical LC systems where extracolumn volume must be carefully controlled.

Direct-connect HPLC inline filter installation and Waters chromatography connection example
Direct-connect inline filter configuration and installation example.

01. Compact Connection

Reduces additional connection components when installed with compatible LC fittings.

02. Simple Installation

Designed for convenient assembly and routine filter maintenance.

03. Easy Frit Replacement

Replace the filter frit when contamination or excessive pressure drop affects performance.

Installation Note: Confirm the connection type, port geometry, operating pressure and instrument compatibility before installation. Always depressurize the LC system before removing or servicing the filter.

How to Choose the Right HPLC Inline Filter

Selecting the correct filter pore size is important for balancing particulate retention, flow resistance and analytical performance. The HP-IF-D2.1n is available with several stainless steel frit options for different filtration requirements.

HPLC inline filter selection guide for different filtration and connection requirements
Inline filter selection for different liquid chromatography requirements.

Available Pore Size Options

Pore Size Filtration Characteristics Selection Guidance
0.2 μm Finer particulate filtration For applications requiring finer particulate control. Evaluate pressure drop and contamination load.
0.5 μm Fine particulate filtration For applications requiring a balance between particulate retention and flow resistance.
2 μm Coarser particulate filtration For applications where larger particle removal and reduced flow resistance are priorities.
Custom Application-specific filtration OEM pore size options according to your filtration and operating requirements.
Selection Tip: A smaller pore size is not always the best choice. Consider the analytical column, mobile phase, flow rate, particulate load and allowable pressure drop when selecting a filter frit.

Technical Specifications

Parameter Specification
Product Name 2.1 mm Direct-Connect HPLC/UHPLC Inline Filter
Catalog Number HP-IF-D2.1n
Product Type High-Pressure Inline Filter
Configuration 2.1 mm Direct-Connect Type
Construction Material 316L Stainless Steel
Filter Element Replaceable Stainless Steel Frit
Standard Pore Sizes 0.2 μm, 0.5 μm, 2 μm
Custom Pore Sizes Available on Request
Connection Design Compact Direct Connection
Dead Volume Low Dead Volume Design
Maximum Operating Pressure Confirm with HIPSOUL for the selected configuration
Applications Analytical HPLC and UHPLC Particulate Filtration
Maintenance Replaceable Filter Frit

Ordering Information

When ordering the HP-IF-D2.1n inline filter, please specify the required frit pore size and confirm the connection compatibility with your chromatography system.

Catalog Number Description Pore Size Options
HP-IF-D2.1n 2.1 mm Direct-Connect UHPLC Inline Filter Assembly 0.2 μm / 0.5 μm / 2 μm / Custom

Standard Package Contents

Component Quantity
UHPLC Inline Filter 1 pc
HPLC Filter Frit 1 pc
Stainless Steel Nut 2 pcs
Stainless Steel Pressure Ring 2 pcs
OEM & Bulk Orders: Customized frit pore sizes and bulk supply are available on request. Please provide your technical requirements and estimated purchase quantity.

Product Video

Direct-Connect HPLC Inline Filter

Explore the product structure and direct-connect filter configuration in our product demonstration video.

  • Compact inline filter design
  • Stainless steel construction
  • Replaceable filtration element
  • Analytical LC applications
HIPSOUL Direct-Connect HPLC Inline Filter

Frequently Asked Questions

What is a direct-connect HPLC inline filter?

A direct-connect HPLC inline filter is a compact particulate filtration device designed to connect directly to compatible LC ports or fittings. It helps prevent solid particles from reaching the analytical column while minimizing additional connection volume.

What is the difference between an HPLC inline filter and a guard column?

An inline filter uses a porous filter frit primarily to remove particulate contaminants. A guard column contains chromatographic stationary phase and can provide additional protection against retained chemical contaminants. The two products perform different functions and may be used together when appropriate.

Which pore sizes are available for the HP-IF-D2.1n?

The standard pore size options are 0.2 μm, 0.5 μm and 2 μm. Additional stainless steel frit pore sizes are available through OEM customization.

Can the stainless steel filter frit be replaced?

Yes. The HP-IF-D2.1n features a replaceable stainless steel frit, allowing the filtration element to be replaced without purchasing a complete new filter assembly. Always depressurize the LC system before servicing the filter.

Does a smaller filter pore size increase back pressure?

A smaller pore size may increase flow resistance, particularly when the frit accumulates contaminants. Actual pressure drop depends on the frit structure, mobile phase viscosity, flow rate and contamination load.

Is this inline filter compatible with Waters and other UHPLC systems?

Compatibility depends on the instrument model, connection thread, port geometry and operating conditions. Please provide your instrument or analytical column connection details so our technical team can confirm the appropriate configuration.

What is the maximum operating pressure of this inline filter?

The HP-IF-D2.1n is designed for high-pressure LC applications. Please contact HIPSOUL to confirm the rated maximum operating pressure for the specific filter configuration before installation.

What information is required for a quotation?

Please provide your required pore size, instrument model, connection type, operating pressure and purchase quantity. For OEM orders, additional dimensional or technical requirements are helpful.

TECHNICAL SUPPORT & OEM SERVICE

Request a Quote

Looking for a low-dead-volume HPLC inline filter or customized stainless steel frits? Share your required pore size, connection details, operating pressure and quantity with our team.