2.1 mm UHPLC Direct-Connect Guard Column – Low Dead Volume Design

Holder No.: P3K0B-00272

Protect your analytical columns with a compact, high-pressure UHPLC guard column featuring a direct-connect holder and replaceable 1.8 μm packed cartridges.

  • Direct-Connect Design — no additional connecting tubing required.
  • Low Dead Volume — helps minimize extracolumn dispersion and peak broadening.
  • High Pressure Rating — up to 13,000 psi (approximately 900 bar).
  • Replaceable Cartridges — 2.1 × 4.0 mm cartridges with 1.8 μm packing.
  • Multiple Stationary Phases — C18, C8, Phenyl and HILIC options.
  • 316L Stainless Steel Holder — designed for UHPLC and LC-MS applications.

Features & Benefits

The HIPSOUL 2.1 mm direct-connect UHPLC guard column is designed to protect analytical columns from particulate contamination and strongly retained sample components while minimizing additional flow-path volume.

Direct-Connect Design

Connects directly to compatible analytical columns without additional connecting tubing, simplifying installation and reducing connection points.

High Pressure Resistance

The holder is rated up to 13,000 psi (approximately 900 bar) for demanding UHPLC applications.

Low Dead Volume

The compact flow path helps minimize extracolumn dispersion, supporting efficient chromatographic separations.

Analytical Column Protection

Helps capture particulate contaminants and strongly retained compounds before they reach the analytical column.

Replaceable Cartridges

Replace the guard cartridge when necessary while retaining the reusable stainless steel holder.

Multiple Phase Options

Select from general-purpose C18, aqueous-compatible C18, wide-pH C18, C8, Phenyl and HILIC stationary phases.

Direct-Connect Structure & Installation

2.1 mm UHPLC Direct-Connect Guard Column by Hipsoul

The direct-connect assembly combines a reusable 316L stainless steel holder with a replaceable 2.1 × 4.0 mm guard cartridge. Its compact design eliminates the need for additional connecting tubing when used with compatible analytical column connections.

01

Select the Cartridge

Choose a stationary phase compatible with your analytical column and mobile phase.

02

Install the Cartridge

Insert the cartridge into the holder according to the specified installation orientation.

03

Connect the Holder

Connect the assembly directly to a compatible analytical column inlet.

04

Check System Performance

Check for leakage, pressure changes and chromatographic performance before routine use.

Installation Note: Always depressurize the LC system before installing or replacing a guard cartridge. Confirm the connection geometry, operating pressure and installation requirements before use.

Typical Applications

Available stationary phase options support a range of pharmaceutical, environmental, food safety and analytical research workflows. Select the guard cartridge according to the analytical column chemistry and method requirements.

USP L1

General-Purpose C18

  • Saponins, flavonoids and polyphenols
  • Veterinary drug residues
  • Hormones and natural products
  • Herbal preparations
USP L1

Water-Compatible C18

  • Cephalosporin antibiotics
  • Water-soluble vitamins
  • Pharmaceutical formulations
  • Highly aqueous mobile phases
USP L1

Water-Compatible & Low-pH C18

  • Acidic mobile phase methods
  • Pharmaceutical impurity analysis
  • Amino acid derivative analysis
  • Polar acidic compounds
USP L1

Wide-pH C18

  • Acidic and alkaline drug analysis
  • Pharmaceutical stability testing
  • Complex pharmaceutical samples
  • Methods requiring a wider pH range
USP L7

General-Purpose C8

  • Hydrophobic pharmaceutical compounds
  • Immunosuppressant drug analysis
  • Herbal mixtures
  • Methods requiring moderate retention
USP L11

Phenyl Stationary Phase

  • Aromatic compounds
  • Botanical extracts
  • Pharmaceutical compounds
  • Methods requiring alternative selectivity
USP L3

HILIC – Hydrophilic Silica

  • Highly polar compounds
  • Hydrophilic pharmaceutical analytes
  • Glutamine-alanyl-glutamine
  • Compounds poorly retained by reversed-phase LC
TECHNICAL SUPPORT

Other Analytical Methods

Need a guard cartridge for a different stationary phase or specialized separation method?

Contact our technical team to discuss your analytical column and application requirements.

Discuss Your Application →

Technical Specifications

Parameter Specification
Product Name2.1 mm UHPLC Direct-Connect Guard Column
Holder Catalog NumberP3K0B-00272
Product TypeAnalytical Guard Column Holder and Replaceable Cartridge
Cartridge Inner Diameter2.1 mm
Cartridge Length4.0 mm
Cartridge Dimensions2.1 × 4.0 mm
Packing Particle Size1.8 μm
Maximum Holder Pressure Rating13,000 psi (approximately 900 bar)
Holder Material316L Stainless Steel
Connection TypeDirect Connection
Stationary Phase OptionsC18, Water-Compatible C18, Low-pH C18, Wide-pH C18, C8, Phenyl, HILIC
pH ToleranceDepends on selected cartridge; see Selection Chart
Typical ApplicationsUHPLC, UPLC and LC-MS analytical column protection
Cartridge ReplacementReplaceable cartridge with reusable holder
Compatibility Note: Confirm the analytical column inlet connection and cartridge chemistry before ordering. The operating pressure of the complete assembly must remain within the limits of all connected components.

Guard Column Selection Chart

Choose the appropriate holder and guard cartridge according to your analytical column dimensions, stationary phase, mobile phase pH and separation requirements.

1. Guard Column Holder

Holder Code Inner Diameter Cartridge Dimensions Connection Application Material
P3K0B-00272 2.1 mm 2.1 × 4.0 mm Direct Connection UHPLC / LC-MS 316L Stainless Steel

2. Guard Column Cartridge

All seven cartridge options listed below feature 1.8 μm packing and are designed for the corresponding 2.1 mm direct-connect guard column holder.

Cartridge Code Stationary Phase USP pH Range Particle Size Typical Applications
P3X0B-00399 General-Purpose C18 L1 2–8 1.8 μm Saponins, flavonoids, polyphenols, veterinary drug residues, hormones and herbal materials.
P3X0B-00400 100% Water-Compatible C18 L1 2–8 1.8 μm Cephalosporin antibiotics, water-soluble vitamins, Docetaxel, Rifaximin, Aciclovir and Nitroglycerin tablets.
P3X0B-00401 Water-Compatible & Low-pH C18 L1 0.5–8 1.8 μm Gentamicin sulfate, Estriol, O-methylsalicylic acid, Nimodipine, Adenosine injection and Aspirin.
P3X0B-00402 Wide-pH C18 L1 1–11 1.8 μm Pantoprazole Sodium, Meropenem, Ranitidine capsules, Moxifloxacin and Octreotide Acetate.
P3X0B-00403 General-Purpose C8 L7 2–8 1.8 μm Tacrolimus, Clindamycin Phosphate, Compound Licorice Oral Liquid and Rifapentine.
P3X0B-00404 Phenyl L11 2–8 1.8 μm Montelukast, Oxytetracycline, Garden Radish Seed and Sophorae Fructus Pills.
P3X0B-00405 Hydrophilic Silica (HILIC-SiO2) L3 2–8 1.8 μm Glutamine-alanyl-glutamine and polar compounds poorly retained by reversed-phase columns.
Selection Note: Application examples are provided as selection guidance. Matching a USP classification alone does not guarantee identical chromatographic selectivity. Confirm stationary phase compatibility and method performance before routine use.

How to Choose the Right UHPLC Guard Column

A properly selected guard column should provide analytical column protection without unnecessarily increasing system pressure or changing chromatographic selectivity.

Match the Stationary Phase

Choose a guard cartridge with chemistry compatible with your analytical column, such as C18, C8, Phenyl or HILIC.

Check Column Dimensions

Use a guard cartridge with suitable dimensions for your analytical column and flow-rate requirements. This series features a 2.1 mm inner diameter.

Confirm Pressure Compatibility

Verify that the holder, cartridge, analytical column and LC system are suitable for the intended operating pressure.

Consider Mobile Phase Conditions

Select a stationary phase compatible with the mobile phase composition, pH and analytical method.

Guard Column vs. HPLC Inline Filter

Comparison UHPLC Guard Column HPLC Inline Filter
Primary Function Protects against particulates and retained chemical contaminants Primarily removes particulate contaminants
Internal Element Packed stationary phase cartridge Porous filtration frit
Selection Criteria Stationary phase, particle size, pH and column compatibility Frit pore size, flow rate and pressure
Maintenance Replace guard cartridge Replace filtration frit
Related Product 2.1 mm Direct-Connect Guard Column 2.1 mm Direct-Connect HPLC Inline Filter

For additional guard column configurations, visit our HPLC Guard Columns product category.

Product Media

2.1 mm Direct-Connect Guard Column

Explore the compact UHPLC guard column design, replaceable cartridge structure and direct-connect configuration.

  • Reusable stainless steel holder
  • Replaceable guard cartridge
  • Compact direct-connect structure
  • Low-dead-volume flow path
  • High-pressure UHPLC applications

Contact our technical team for installation guidance and analytical column compatibility.

2.1 mm UHPLC Direct-Connect Guard Column – Product Video

Frequently Asked Questions

What is a 2.1 mm UHPLC direct-connect guard column?

It is a compact analytical column protection device consisting of a reusable holder and a replaceable packed cartridge. It connects directly to compatible analytical columns, helping minimize additional extracolumn volume.

What is the maximum operating pressure?

The guard column holder is rated up to 13,000 psi, approximately 900 bar. The actual operating pressure must remain within the limits of the selected cartridge and all connected LC components.

Do I need additional tubing or fittings?

The direct-connect design eliminates the need for additional connecting tubing when used with compatible analytical column connections. Confirm the connection geometry before installation.

Which stationary phases are available?

Available options include general-purpose C18, water-compatible C18, water-compatible low-pH C18, wide-pH C18, C8, Phenyl and HILIC silica. Refer to the Selection Chart for catalog numbers and pH ranges.

Can I replace the cartridge without replacing the holder?

Yes. The guard cartridge is replaceable, allowing the stainless steel holder to be reused. Always depressurize the LC system before cartridge replacement.

When should I replace a UHPLC guard cartridge?

Consider replacement when system backpressure increases, peak shape deteriorates or contamination affects chromatographic performance. Replacement frequency depends on sample cleanliness, mobile phase conditions and method requirements.

What is the difference between a guard column and an inline filter?

A guard column contains packed stationary phase material and helps protect against particulates and retained chemical contaminants. An inline filter primarily removes particles using a porous frit.

Is this guard column suitable for LC-MS applications?

The holder is designed for UHPLC and LC-MS analytical workflows. Confirm connection compatibility, stationary phase, mobile phase and operating conditions for your specific LC-MS method.

What information should I provide when requesting a quotation?

Please provide your analytical column brand and model, stationary phase, particle size, operating pressure, required cartridge code if known, and quantity.

Need help selecting the right guard cartridge? Contact our technical team.