Conventional Prep Empty HPLC Column for Clinical Chromatography
Previous slide Next slide Conventional Prep Empty HPLC Column, ID20*1100mm for Clinical Chromatography – Get the best quality Conventional Prep Empty HPLC Column for your
Home » Portfolio Items » Liquid Chromatography C18-G ODS Columns
C18-G ODS Columns are general purpose, reversed-phase C18 columns available in 5 μm and 10 μm particle sizes.
A new generation ODS column with organic silica blend matrix.
Excellent separation selectivity with C18 silica gel;
Excellent resistance to acids and bases, effective against all types of compounds;
It is an ODS liquid chromatography column that combines durability, good peak display and reproducibility, and low pressure;
It is an hplc column with a wide range of applications.
Particle Size | 5um, 10um |
Pore Size | 100 Å |
Carbon Content | 18% |
End-capping | One time closing |
PH | 1~12 |
Temperature | PH 1~7:70℃ PH 7~12:50℃ |
● For use at lower pressures in a wide range of new and old equipment models;
● It is also convenient to use a high viscosity solvent such as methanol as a drenching solution;
● When dissolving samples in a solvent with high solvency power such as acetonitrile, the injection volume can be more than two times that of conventional products.
For chloromastine or other basic compounds that tend to drag and are more difficult to analyze, the USHA C18-G column is easy to use to obtain good peak shapes without trailing. It can be used in a wide pH range (1~12), especially under strong alkaline or high-temperature conditions, and has a lifetime several times longer than the average alkaline-resistant (mixed) C18 column on the market; it also has good acid resistance, which is even better when used in conjunction with a uHPLCs guard column. It is the first choice for each insulin-like substance and is widely used for the analysis of polar and hydrophobic substances.
Liquid Chromatographic Column Specifications(mm) | |
2.1*30, 2.1*50, 2.1*75, 2.1*100, 2.1*150 | 3.0*30, 3.0*50, 3.0*100, 3.0*150 |
4.6*30, 4.6*50, 4.6*100, 4.6*150, 4.60*250 | 10*50, 10*100, 10*150, 10*250 |
20*50, 20*150, 20*200, 20*250, 20*300 | 21.2*150, 21.2*250 |
30*150, 30*250 | 50*150, 50*250 |
– In order to maintain the initial performance of the chromatographic column stably for as long as possible, during use, it should be used according to the precautions recorded in the instruction manual of each chromatographic column, but it is also necessary to perform daily maintenance on the column. Such as optimizing the analysis conditions (eluent, feed flow rate, injected sample, etc.), cleaning the chromatographic column regularly, etc.
– In order to reduce the damage of liquid chromatographic columns, uHPLCs recommends that you take some precautions when using chromatographic columns. For example:
(1). Add an in-line filter to the liquid phase system;
(2). Use a guard column at the front of the column;
(3). Purify the sample.
– In actual work, the storage of the liquid chromatography column will also affect the service life of the column. Then for the storage of chromatographic columns, there are also the following suggestions:
It should be stored under conditions close to those of the commonly used mobile phase. Also, be sure to remove buffer salts, acids, etc. from the system.
Store the chromatographic column in the corresponding solvent according to the instructions, remove the chromatographic column from the system, and block both ends with plugs.
Previous slide Next slide Conventional Prep Empty HPLC Column, ID20*1100mm for Clinical Chromatography – Get the best quality Conventional Prep Empty HPLC Column for your
Previous slide Next slide HPSIF-POC1 Solvent Inlet Filter SS, SS/PCTFE Threaded For 1/8”O.D. Teflon Tubing Contact Us Short Description: Product characteristics. 1) stable shape, impact
Previous slide Next slide 20*250mm Stainless Steel Preparative HPLC Empty Column For Chemistry Lab Equipment, 0.1um Short Description: Empty HPLC Column (Each column blank kit)
Superior Quality, On-demand Customization,Continuous Optimization,
Strictly control the manufacturing process,
Intimate Service, Go All Out.